The function of the BOECO Ultrasonic Milk Analyzer is to make quick analyses of milk samples directly after milking, at collecting and during processing.

The BOECO Milk analyzer makes quick analyses of milk and liquid dairy products as: Cow milk, UHT milk, Sheep milk, Goat milk, Buffalo milk, Camel milk, Whey, Cream (up to 45%), Skimmed milk (0,01% FAT, Ice-cream mixtures, Concentrated milk (up to 1160 kg/m3 ), Yogurt, Flavoured milk, Recovered milk.

Each unit will be delivered with 3 calibrations (standard are sheep, cow and UHT milk)

The standard model LAC-S has one peristaltic pump for the sample, the LAC-SA models have two pumps, the second one for automatic cleaning.

  • Direct measurement of cold milk samples, starting at 5°C
  • No need of periodical calibration
  • The measurement accuracy is not dependant on milk’s acidity
  • High-end ultrasonic technology for analyzing any kind of milk
  • Dimensions 100x223x216 mm (WxLxH)
  • Weight: < 3 kg
  • Power: Input 100-240V ~1,6 A max, 50/60 Hz, Output +12V 4.17 A min


The following Parameters can be measured from the Ultrasonic system:
Fat, Solid-non-fat (SNF), Density, Protein, Lactose, Milk sample temperature, Added water, Salts, Freezing point

The following Parameters can be measured from integrated systems:
pH (together with a electrode), Conductivity, Inhibitors

CodeDescription
BOE 5290090BOECO LAC-S-60 0.001°C Milkanalyzer, Standard Model, 60 sec. measuring time, with pH measuring system USB/RS 0.05% 232 data port, USB flash drive
BOE 5290950BOECO LAC-SA-50 Milkanalyzer, Standard 0,05% Automat (2 pumps), 50 sec. measuring time, with pH 0,17% measuring system, USB/RS 232 data port, USB flash drive
BOE 5291950BOECO LAC-SA-50 Milkanalyzer, Standard Automat (2 pumps), 50 sec. measuring time, with pH 0,05% measuring system and integrated Conductivity measurement, real time clock USB/RS 232 data port, USB flash drive
Option: BOE 5451160 High-fat (45%) / Density 1160 kg/m3 measuring function
ParameterMeasuring rangeAccuracy
Fatfrom 0,01% to 25% (option 45 %)± 0.1%
SNF (Solids-non-fat)from 3% to 15%± 0.15%
Densityfrom 1015 to 1140 kg/m3(option 1160 kg/m3)± 0.3 kg/m3
Proteinfrom 2% to 7%± 0,15%
Lactosefrom 0.01% to 6%± 0.15
Added Water contentfrom 0% to 70%± 3.0%
Temperature of milkfrom 1°C to 40°C± 1°C
Freezing pointfrom -0,4 to -0,7°C± 0.001°C
Saltsfrom 0,4 to 1,5%± 0.05%
pHfrom 0 to 12± 0,05%
Total solidsfrom 0 to 50 %± 0,17%
Option: Conductivity0,15% from 3 to 14 (mS/cm)± 0,05%